Cryoglobulin


Test Information

Test Name

Cryoglobulin

Department

Transfusion

Preferred Specimen

2x Plain tubes

Testing Location

PLBOP


Collection Information

Main Lab Only

Yes

Availability

Monday - Thursday collection only

Preparation

  • Pre warm tubes, use heat block
  • Refer to Patient Services Test Reference Manual

Delivery and Handling

Transport at 37C; deliver to lab ASAP; DO NOT send through Lamson


Processing Information

Registration Code

CRYO

Notes

  • If form indicate "Cryoprecipitants", register both CRYO and CRYF (Refer to Cryofibrinogen)
  • Follow Specimen Services Special Handling procedure
  • Once processed, aliquot tubes can be sent at room temperature to PLBOP
  • If positive and requested by Transfusion, add on CRYS, sample send ambient to LabPlus

Methodology

Interpretations

View Interpretations

Send Away Transport

If positive and requested by Transfusion, add on CRYS, sample send ambient to LabPlus